INTRODUCTION

The true umbilical cord knot is relatively rare and its prevalence varies from 0.3% to 2.1%'. It can be defined as the entanglement of a segment of the umbilical cord as a result of fetal movements, and in most cases occurs without any clinical significance, which makes intra-uterine diagnosis difficult2,3.

It is believed that the cord knot is formed between the 9th and 12th weeks of gestation, since during this period there is a greater volume of amniotic fluid and a greater fetal circulation3. Some authors suggest that the true cord knot is formed intrapartum, which would not contribute to an investigation during the prenatal period to diagnose this fact2,4. On the other hand, there are factors that increase the predisposition to this event5.

The pre-birth fetal mortality rate increases 4 to 10 times in such fetuses when compared to the normal obstetric population, which makes extremely important the prenatal diagnosis of the cord knot 3,6.

Considering the low prevalence and possible complications resulting from this clinical finding, this study aimed to report the case of a true umbilical cord knot.

CASE REPORT

A 19-year-old primigravid at 39 weeks’ gestation, admitted to a philanthropic maternity hospital. The patient performed the 10 prenatal regular consultations which evolved with no intercurrences and with normal complementary exams. The patient underwent four ultrasound examinations without the identification of presence of umbilical cord entanglement. At admission, the patient presented cervical dilation of 5 cm, 90% uterine cervix erection, intact pocket, fetus at -3 De Lee’s plan, 144 fetal heart beats, uterine dynamic of 3/30”/10’. Labor was followed through a partograph where all parameters were evaluated, and there was no evidence of fetal distress or asphyxia on exams. At the end of 4 hours it has evolved to vaginal delivery without intercurrences with medio-lateral episiotomy and identification by direct visualization of long umbilical cord and true knot in the median third without compromising the flow in the cord (Figures I and II).

Male newborn, alive, assisted by the pediatrician in the delivery room, active and reactive, with presence of preserved tonus, clear amniotic fluid without lumps, adequate respiratory rate, 3,045 kg, apgar 9/10, referred for routine procedures and general care. On the first day of puerperium, physical and clinical examinations of both patients were performed without alterations. Newborn in exclusive, active and reactive breastfeeding, preserved tonus, vital signs evaluated and regular as expected for age, existing reflexes, preserved excretory physiological functions, evaluation of screening tests following the current guidelines of the Unified Health System (SUS).

The conduct was hospital discharge after routine procedures and guidelines. The study volunteers signed a free and written informed consent form, authorizing the use of the previously presented data. In addition, it was previously submitted and approved by the institutional Research Ethics Committee according to Resolution 466/12 of the National Health Council and in accordance with the Helsinki Resolution.

DISCUSSION

The true cord knot is a rare change with few studies in the literature, the research was performed with the term “true knot umbilical cord” OR “umbilical cord true knot”, and we found 57 articles approaching the topic in Medline, which justifies the interest in this case.

There are factors that increase its predisposition, which include male fetus, long umbilical cord, prolonged pregnancy, polyhydramnios, amniocentesis, small-sized fetuses, monoamniotic twins, gestational diabetes mellitus, chronic hypertension, anemia, multiparity, previous abortions, advanced maternal age, obesity and prolonged pregnancy1,3,5.

In this case, the risk factors described in the literature were found as follows; the presence of a long umbilical cord and a newborn male, who did not present clinical alterations5,7,8. The studies indicate that, in most cases, the cord knots are loose in the intrauterine phase or are formed during delivery and, therefore, do not cause significant perinatal problems2,4. The main concern, however, is the possibility of a tight knot during the fetal phase that can generate changes in the umbilical blood flow and promote, as a consequence, interruption of the circulation, which can lead to asphyxia and fetal death intrauterine, especially at the time of labor3,4.

In the literature we find reports on the importance of the complementary method, obstetric ultrasonography (OBU), to diagnose the true cord knot, which made it possible to perform it during the prenatal period9,10. However, there are still limitations in the antenatal diagnosis of this condition, including inadequate prenatal care, either due to the lack of trained professionals to interpret the data suggestive of the condition or the absence of a 2-D, 3-D and Doppler colorful methods; impossibility of visualizing any umbilical cord within the uterus; and the absence of a distinctive sonographic aspect of a true cord knot2,11,12,13. However, some data obtained through OBU may suggest the possibility of umbilical cord entanglement, such as polyhydramnios and long umbilical cord2,4, since the latter was observed in the present case described herein. In view of the above, we suggest the improvement of ultrasound techniques by professionals who deal with care of pregnant women and training to better visualize the signs suggestive of this condition.

Due to the high risk of complications and rarity of this condition, there is little evidence in the literature about obstetric behavior at delivery, and the choice of c-section can be considered if the diagnosis of a true cord knot is performed, and vaginal delivery should not be encouraged because of the possible risks to the maternal-fetal binomial2. However, this indication is still very controversial in the literature and we can find obstetricians who face this condition differently2. In the present case the decision for vaginal delivery was due to the favorable conditions and due to the lack of knowledge of the occurrence of the cord knot.

The entanglement of the umbilical cord as a result of fetal movements can occur without clinical alterations, which makes intra-uterus diagnosis difficult4. The importance of the case is due to the severity of the complications generated, even though rare, leading the newborn to death14,15,16. In the case reported, the newborn was in good general condition, adequate vital signs and no changes until the moment of hospital discharge.

CONCLUSION

The true cord knot is characterized by the presence of a loop in a portion of the umbilical cord extension that, for the most part, occurs without any clinical significance, as in the case presented in this report, but can generate serious complications such as decreased umbilical blood flow, asphyxia and even intrauterine fetal death. However, it should be emphasized that in most cases the knot is unknown until the moment of delivery, which may contribute greatly to intrauterine complications.

REFERENCES

1 - Choudhary R, Choudhary SB. True Knot of the Umbilical Cord - 3D Power Doppler Imaging. J Fetal Med. 2015 ; 1: 189-90.

2- Guzikowski W, Kowalczyk D, Wiecek J. Diagnosis of true umbilical cord knot. Archs Med Sci. 2014 ; 10 : 91-5.

3 - kechebelu JI, Eleje GU, Ofojebe CJ. True umbilical cord knot leading to fetal demise. Ann Med Health Sci Res. 2014 ; 4 : 155-8.

4 - Hasbun J, Alcalde JL, Sepulveda W. Three-Dimensional Power Doppler Sonography in the Prenatal Diagnosis of a True Knot of the Umbilical Cord. J Ultrasound Med. 2007 ; 26 : 1215-20.

5 - Cajal CLR, Martínez RO. Four-dimensional ultrasonography of a true knot of the umbilical cord. American Journal of Obstetrics Gynecology. 2006 ; 195 : 896-8.

6 - Rodriguez N, Angarita AM, Casasbuenas A, Sarmiento A. Three-dimensional high-definition flow imaging in prenatal diagnosis of a true umbilical cord knot. Ultrasound Obstet Gynecol. 2012 ; 39 : 245-6.

7 - Srinivasan A, Graves L. Four true umbilical cord knots. J Obstet Gynaecol Can. 2006 ; 28 : 32-5.

8 - Contreras MO, Bernal JE. Comprendiendo el cordón umbilical. Patología Revista Latinoamericana. 2013 ; 51 : 200-5.

9 - Abuhamad A. Theree-dimensional ultrasound with color Doppler imagingof na umbilical cord true knot. Ultrasound Obstet Gynecol. 2014 ; 43 : 360.

10 - Gembruch U, Baschat AA. True knot of the umbilical cord: transient constrictive effect to umbilical venous blood flow demonstrated by Doppler sonography. Ultrasound Obstet Gynecol. 1996 ; 8 : 53-6.

11 - Triunfo S, Rosati P, Guariglia L, Scambia G. Prenatal diagnosis and surveillance of a true umbilical knot by two- and three-dimensional. Minerva Ginecol. 2014 ; 66 : 127-9.

12 - Bakas P, Papadakis E, Hassiakos D, Liapis A. Second-trimester miscarriage and umbilical cord knot. Case report and review of the literature. Clin Exp Obstet Gynecol. 2013 ; 40 : 448-51.

13 - Scioscia M, Fornalè M, Bruni F, Peretti D, Trivella G. Four-dimensional and Doppler sonography in the diagnosis and surveillance of a true cord knot. J Clin Ultrasound. 2011 ; 39 : 157-9.

14 - Nomura ML, Franzin CMM, Milanez H, Marussi EF, Silva JLCP. Gestação monoaminiótica e entrelaçamento de cordão umbilical: relato de caso e revisão de literatura. Rev Bras Ginecol Obstet. 2010 ; 32 : 94-8.

15 - Ramón Y Cajal CL, Martínez RO. Prenatal diagnosis of true knot of the umbilical cord. Ultrasound Obstet Gynecol. 2004 ; 23 : 99-100.

1. Medicine Student of the Faculty of Medical Sciences and Health of Juiz de Fora - SUPREMA - MG, Brazil (2016) - Student 2. Medicine Student of the Faculty of Medical Sciences and Health of Juiz de Fora - SUPREMA - MG, Brazil (2016) - Student 3. Physician graduated at Faculty of Medical Sciences and Health of Juiz de Fora - SUPREMA - MG, Brazil - Physician 4. Medicine Student of the Faculty of Medical Sciences and Health of Juiz de Fora - SUPREMA - MG, Brazil (2016) - Student 5. Medicine Student of the Faculty of Medical Sciences and Health of Juiz de Fora - SUPREMA - MG, Brazil (2016) - Student 6. PhD in Exercise and Sport Sciences - UGF. Postdoctorate ant University of Brasília (UNB) - Professor of the Faculty of Medical Sciences and Health of Juiz de Fora - SUPREMA - MG, Brazil

Correspondência: Faculdade de Ciências Médicas e da Saúde de Juiz de Fora Plínio Santos Ramos Alameda Salvaterra n° 200, Bairro: Salvaterra. Juiz de Fora - MG. CEP: 36033-003 Telefone/fax:2101-5000pliniosramos@suprema.edu.br

Instituição: Faculdade de Ciências Médicas e da Saúde de Juiz de Fora - SUPREMA MG, Brasil Hospital e Maternidade Therezinha de Jesus - Juiz de Fora -MG, Brasil